Rigid-flex engineering

Rigid-Flex Stackup Submission Checklist

A rigid-flex stackup submission must show which layers exist in each region and how those regions connect. A single total layer count cannot describe the flex thickness, bend zone, coverlay, transition or interconnect requirements.

rigid flex panel
Rigid-flex panel — product photograph supplied by RAYPCB. The submission example is an explanatory document layout, not the construction record for this board.

The practical decision

Send a region map, region-specific stacks and the mechanical use conditions together. Link each drawing region to its stack identifier, then identify the copper layers that continue through the flexible section.

  1. Map regionsRigid A + flex F + rigid B
  2. Define stacksMaterials + continuity
  3. State motionEnvelope + bend conditions
  4. Release setDrawings + revisions

A stackup submission that engineering can review

A folded 3D model communicates shape, but it should accompany the dimensioned flat outline and a region-specific construction drawing. Use consistent region names in CAD output, fabrication drawings and stack tables.

DocumentIncludeCheck before sending
Region mapRigid/flex boundaries, named regions and flat outlineEvery region points to a defined stack
Region stacksCopper, dielectrics, adhesives, coverlay and tolerancesLayer order and material callouts agree
Continuity mapConductors/layers continuing between rigid sectionsFlex copper is distinct from total rigid-layer count
Mechanical definitionBend zone, direction, radius, angle and envelopeReference surfaces and units are explicit
Use conditionsInstall-once or repeated motion, cycles and environmentRequirements are not predicted fatigue results
Fabrication detailsVia spans, transitions, openings and stiffenersDetails do not conflict with bend zones
Electrical targetsImpedance type, target, tolerance, layer and referenceRegion transitions are identified

Example: two rigid islands joined by a flex section

Illustrative mapping: regions R-A and R-B use stack S-R; connecting region F-1 uses stack S-F. Explicitly list the copper layers that continue through F-1 and those that terminate at each transition. This explains how to label the submission; it does not select qualified materials, thicknesses or a bend radius.

RegionReferenced informationQuestion to close
R-A / R-BS-R stack, component faces and via layer pairsAre the rigid regions identical?
F-1S-F stack, continuing copper and coverlayWhat is the finished flex thickness?
TransitionBoundary dimensions and construction detailWhere does bending begin?
Bend zoneDirection, radius reference and motion conditionsIs use install-once or dynamic?

For construction selection and layer mapping, continue to the rigid-flex stackup guide.

Resolve drawing conflicts before requesting production

Compare the quote layer count with the region map. Identify coverlay openings and exposed contacts. Check that a proposed stiffener does not occupy an intended bend zone and that the assembled envelope includes connectors and enclosure features. Mark uncertain requirements as open questions rather than supplying an arbitrary thickness or bend multiplier.

Release one matched drawing set

Provide agreed design exports, fabrication outputs, drill data and a readable fabrication drawing with a revision manifest. If engineering proposes a different construction, review the affected mechanical and electrical requirements before approval. Use the separate stackup guide for design options; this resource checks the completeness of the submission.

With the submission assembled, discuss rigid-flex manufacturing and design review using the same file revision.

Working document

Prepare your handoff checklist

Open the editable text worksheet, save a copy and record the requirement, owner and evidence for each item. Keep unanswered points visible when requesting review.

  1. PCB revision, quantity and region names
  2. Dimensioned flat outline and installed envelope
  3. Region stacks and material/thickness tolerances
  4. Copper-layer continuity through each flex region
  5. Coverlay, adhesives, transitions and stiffeners
  6. Bend radius reference, angle, motion and required cycles
  7. Via spans, fill and keepouts
  8. Impedance targets and reference layers
  9. Drawing manifest, open questions and approver

The Contact page is a separate enquiry step. Attach your completed worksheet and relevant files there using its available submission options; this page does not automatically transfer your answers.

Questions before you release the files

Can I submit only a folded 3D model?

Also provide a flat dimensioned outline, region map and construction details. A model alone may not communicate material or manufacturing intent.

Is stiffened flex the same as rigid-flex?

No. A mechanical stiffener does not automatically create an electrically interconnected rigid multilayer region. Identify the actual construction.

Can a radius ratio approve repeated flexing?

No. Dynamic suitability depends on construction and use conditions. Provide the motion requirement for review; a ratio is not a fatigue-life guarantee.

Continue with the next engineering task