Rigid-flex engineering
Rigid-Flex Stackup Submission Checklist
A rigid-flex stackup submission must show which layers exist in each region and how those regions connect. A single total layer count cannot describe the flex thickness, bend zone, coverlay, transition or interconnect requirements.

The practical decision
Send a region map, region-specific stacks and the mechanical use conditions together. Link each drawing region to its stack identifier, then identify the copper layers that continue through the flexible section.
- Map regionsRigid A + flex F + rigid B
- Define stacksMaterials + continuity
- State motionEnvelope + bend conditions
- Release setDrawings + revisions
A stackup submission that engineering can review
A folded 3D model communicates shape, but it should accompany the dimensioned flat outline and a region-specific construction drawing. Use consistent region names in CAD output, fabrication drawings and stack tables.
| Document | Include | Check before sending |
|---|---|---|
| Region map | Rigid/flex boundaries, named regions and flat outline | Every region points to a defined stack |
| Region stacks | Copper, dielectrics, adhesives, coverlay and tolerances | Layer order and material callouts agree |
| Continuity map | Conductors/layers continuing between rigid sections | Flex copper is distinct from total rigid-layer count |
| Mechanical definition | Bend zone, direction, radius, angle and envelope | Reference surfaces and units are explicit |
| Use conditions | Install-once or repeated motion, cycles and environment | Requirements are not predicted fatigue results |
| Fabrication details | Via spans, transitions, openings and stiffeners | Details do not conflict with bend zones |
| Electrical targets | Impedance type, target, tolerance, layer and reference | Region transitions are identified |
Example: two rigid islands joined by a flex section
Illustrative mapping: regions R-A and R-B use stack S-R; connecting region F-1 uses stack S-F. Explicitly list the copper layers that continue through F-1 and those that terminate at each transition. This explains how to label the submission; it does not select qualified materials, thicknesses or a bend radius.
| Region | Referenced information | Question to close |
|---|---|---|
| R-A / R-B | S-R stack, component faces and via layer pairs | Are the rigid regions identical? |
| F-1 | S-F stack, continuing copper and coverlay | What is the finished flex thickness? |
| Transition | Boundary dimensions and construction detail | Where does bending begin? |
| Bend zone | Direction, radius reference and motion conditions | Is use install-once or dynamic? |
For construction selection and layer mapping, continue to the rigid-flex stackup guide.
Resolve drawing conflicts before requesting production
Compare the quote layer count with the region map. Identify coverlay openings and exposed contacts. Check that a proposed stiffener does not occupy an intended bend zone and that the assembled envelope includes connectors and enclosure features. Mark uncertain requirements as open questions rather than supplying an arbitrary thickness or bend multiplier.
Release one matched drawing set
Provide agreed design exports, fabrication outputs, drill data and a readable fabrication drawing with a revision manifest. If engineering proposes a different construction, review the affected mechanical and electrical requirements before approval. Use the separate stackup guide for design options; this resource checks the completeness of the submission.
With the submission assembled, discuss rigid-flex manufacturing and design review using the same file revision.
Working document
Prepare your handoff checklist
Open the editable text worksheet, save a copy and record the requirement, owner and evidence for each item. Keep unanswered points visible when requesting review.
- PCB revision, quantity and region names
- Dimensioned flat outline and installed envelope
- Region stacks and material/thickness tolerances
- Copper-layer continuity through each flex region
- Coverlay, adhesives, transitions and stiffeners
- Bend radius reference, angle, motion and required cycles
- Via spans, fill and keepouts
- Impedance targets and reference layers
- Drawing manifest, open questions and approver
The Contact page is a separate enquiry step. Attach your completed worksheet and relevant files there using its available submission options; this page does not automatically transfer your answers.
Questions before you release the files
Can I submit only a folded 3D model?
Also provide a flat dimensioned outline, region map and construction details. A model alone may not communicate material or manufacturing intent.
Is stiffened flex the same as rigid-flex?
No. A mechanical stiffener does not automatically create an electrically interconnected rigid multilayer region. Identify the actual construction.
Can a radius ratio approve repeated flexing?
No. Dynamic suitability depends on construction and use conditions. Provide the motion requirement for review; a ratio is not a fatigue-life guarantee.
Continue with the next engineering task
Technical references
- Altium Designer: rigid-flex design documentation
CAD documentation for region-specific stacks and bend definitions; it does not approve a fabrication process.