RAYPCB · ENGINEERING GUIDE
Isola IS680 PCB: RF Dk Options and Phase Planning
Isola IS 680 is an RF laminate family with several dielectric options. A useful IS 680 PCB specification therefore names more than the family: it identifies the required Dk option, thickness, copper and electrical model. This page focuses on phase-sensitive construction and the evidence needed before releasing RF artwork.
The Isola PCB overview covers the broader range. IS 680AG is a different designation and its data should not be silently used for an IS 680 drawing.

Select a dielectric option with its measurement context
The official IS 680 revision C sheet lists multiple Dk options rather than one universal value. For example, it reports Dk 3.33 and Df 0.0030 at 10 GHz, with IPC 2.5.5.5 and Bereskin stripline contexts respectively. That pair is not a property assignment for every IS 680 construction.
Preserve the complete suffix, method, frequency and supplied thickness. A nearby option can require a different line width or resonator geometry. If the source only provides a nominal catalog value, ask for the appropriate design data and tolerance before treating it as a production model.
Evidence and construction decision
| Item | Source or model boundary | Action for the design review |
|---|---|---|
| Product | IS680 discrete dielectric options | Do not replace with IS680AG data. |
| Example data pair | Dk 3.33 / Df 0.0030 at 10 GHz in cited sheet | Retain each property test method and actual option. |
| Delay tool | Homogeneous ideal TEM path | Not microstrip effective permittivity or phase qualification. |
Homogeneous TEM delay illustration
Homogeneous TEM delay illustration
Use the current inputs and keep the assumptions
Start with the example only to inspect the units and the calculation boundary. Replace every assumption with a value tied to your own document or measurement. An empty numeric field is not zero. The review-reference field is a local label; avoid entering customer names, confidential part numbers or other private information into a public worksheet.
After calculating, read the notes alongside the numerical result. Changing any input invalidates the displayed result and disables its download until you calculate again. For a comparison, keep the units, geometry, material condition and measurement boundary consistent. A long decimal result does not imply equally precise input data. The downloadable record stays on your device and can be attached manually to an inquiry. It is not automatically transferred into the Contact form.
If an input is unknown, identify the person or document needed to resolve it. Do not fill a gap with a favorable generic value simply to obtain a result. You can request a material or fabrication review without using the tool. The arithmetic illustrates a relationship; it does not accept a construction, certify a material, establish current pricing or replace a supplier process specification.
| Input | What to establish before using it |
|---|---|
| Review reference | Nonconfidential revision label. |
| Relative permittivity | Bulk material value for a homogeneous ideal TEM path; not a microstrip effective Dk. |
| Electrical path length · mm | One-way uniform propagation length. |
Optional cost comparison from your own allowances
Use a quotation or a clearly labeled internal assumption for each input. Keep the quantity, construction and inspection scope the same when comparing alternatives. This uncalibrated planning model adds entered values; it contains no current market rates and does not issue a RAYPCB quotation. You can contact the team without completing it.
Optional project allowance comparison
Turn the circuit requirement into a stackup question
A phase-matched feed network, resonant filter and simple controlled-impedance line have different sensitivities. State the frequency range and which result must be controlled. The fabricator needs to know whether dielectric thickness, line shape, copper or a mechanical interface is especially critical.
For a hybrid build, identify the bonding interval and adjoining layers as well as the RF core. A change in the neighboring dielectric or reference plane can alter the field distribution. The material name alone does not describe the circuit's electromagnetic environment.
| Review item | What to establish |
|---|---|
| Exact option | IS680 dielectric option, thickness and copper. |
| Electrical basis | Method, frequency and model geometry together. |
| Verification | Define coupon and reference-plane boundary. |
| Model limit | Homogeneous delay is not microstrip validation. |
Use delay arithmetic within a homogeneous model
The worksheet calculates ideal propagation delay from path length and relative permittivity. With a hypothetical relative permittivity of 4 and a 100 mm uniform path, the one-way delay is approximately 667 ps. The example demonstrates the square-root relationship, not an IS 680 transmission-line prediction.
Microstrip fields occupy both dielectric and air, and actual structures can be dispersive. A bulk Dk should not be inserted as an effective permittivity without justification. Use the appropriate solver and measured construction when phase error or impedance tolerance controls the design.

Keep dielectric loss separate from conductor loss
The substrate contributes only part of the route attenuation. Copper roughness, trace shape, surface finish and transitions can matter, especially as frequency increases. A low Df is useful information but cannot certify the complete RF path.
For a digital-channel comparison, Tachyon 100G owns a different task. For an epoxy loss-budget tradeoff, I-Speed provides a separate workflow. Those comparisons should start from the circuit requirement, not from a ranking of isolated material numbers.
Agree the evidence that will represent the RF construction
Specify coupon geometry, reference planes and the relevant measurement boundary where electrical verification is required. A coupon for one line type cannot automatically represent every bend, launch or resonator. Keep acceptance limits with the test definition.
If evaluating N4000-13, compare exact construction and frequency-qualified data. The optional cost worksheet can organize matched quoted allowances, but it does not decide RF equivalence or contain an IS 680 material price.
Prepare an RF-specific inquiry
Send the exact IS 680 option, stackup, copper type, geometry-sensitive regions, operating band and required electrical evidence. Include quantity, finish, mechanical constraints and the policy on alternatives. Mark any input that is still an assumption.
The manufacturing response should identify the proposed construction and open deviations before artwork is frozen. Material availability and the test scope remain project-specific. A local worksheet download can accompany the inquiry, but its arithmetic does not approve the RF circuit or qualify the finished board.
Move from a material name to a reviewable RF stackup
State the channel reference planes, frequency range, routing length, copper construction, transitions and interface assumptions together. A laminate loss-tangent value is one input to that system. It is not a complete insertion-loss measurement or a guarantee that a data rate will work.
Use comparable measurement or modeling conditions when screening alternatives. Material changes can require geometry changes to preserve impedance, and copper roughness can alter the result independently of the resin system. Keep the proposed stackup and the channel analysis synchronized through fabrication review.
For procurement, identify the properties that are fixed and the alternatives that can be evaluated. Request evidence at the relevant construction and frequency rather than a broad low-loss label. Compare total delivered scope and validation effort alongside material price. A shorter or better-routed channel may change the tradeoff more than replacing a material name alone.
An RF material request should identify what the circuit is sensitive to. An impedance-controlled feed line, a phase-matched network and a resonant structure may respond differently to a material or thickness change. State the frequency range and the relevant performance boundary before asking whether a proposed laminate is equivalent.
Separate exact-grade evidence from product-family context. A shared processing guide may cover several names without making their electrical data identical. A recognition record may establish a product identity without supplying a design Dk. A neighboring catalog entry may be current while the original drawing uses a historical designation. Keep these distinctions in the handoff.
For hybrid boards, record the bonding material and adjacent layers as well as the RF core. The final geometry and process can affect the electrical result. Ask the fabricator to identify any proposed changes to copper, dielectric thickness or treatment before accepting a quote as equivalent to the analyzed design.
The evidence worksheet and physical models serve limited tasks. They do not authenticate a source, solve an arbitrary RF circuit or establish the availability of an unverified grade. A direct engineering inquiry is appropriate when the missing information is the main obstacle; the visitor does not need to complete a calculator first.
Standards, source context and limits
Use the edition, amendment and material-document revision named in the purchase agreement. A standards title, marketing label or supplier product family does not establish that a particular lot meets a requirement. Public summaries are useful for scope; the controlled specification and applicable test method govern acceptance.
The examples on this page are illustrative engineering scenarios. They are not RAYPCB production records or guaranteed material values. Source links identify the organizations responsible for the referenced information. Confirm applicability to the exact grade, construction and test condition before carrying a number into a drawing or qualification report. Sources were reviewed on 3 October 2026. A public catalog search is not proof that an unlisted product never existed. Where the exact designation or current technical sheet could not be verified, this page provides a clarification workflow rather than an invented material specification. Current supply, construction availability and qualification remain separate questions.