A layout review organized around the transition
| Location | Show in the design | What the reviewer checks |
|---|---|---|
| Rigid region | Component lands, mounting features, hole spans and copper layer assignment | Whether the rigid construction supports assembly and connects to the intended flex layers. |
| Rigid-to-flex boundary | Dimensioned boundary, coverlay termination and a controlled keepout | Registration and mechanical stress are considered together; a generic clearance is not a qualified rule. |
| Bend zone | Bend direction, conductor direction, width changes and any vias | Avoid abrupt conductor changes in the moving span; review any unavoidable feature individually. |
| Connector tongue | Exposed side, copper finish, finished thickness and local stiffener | Connector drawing and total local thickness agree; the stiffener is not treated as a copper layer. |
| Return path | Reference copper through the flex and transitions | The signal has a defined electrical return; plane changes require an electrical review. |
Select the flexible base film, copper type, adhesive system and coverlay together. A lower-loss dielectric does not by itself establish bend endurance; a mechanically thin section does not by itself provide the required impedance.
Worked review scenario: a six-layer rigid board routes a controlled-impedance signal on L1, but only L3–L4 continue through its flex. First relocate or transition that route in the rigid section, then define its reference conductor across the flex. Recalculate the electrical geometry for the covered flex construction instead of carrying over the L1 microstrip width. Review the via and transition discontinuity separately.
Use the stackup example for layer continuity, and the capability review for the project-specific manufacturing limits.
Give every region a name and a physical purpose

Start with a flat board outline and assign identifiers to the rigid islands and flexible spans. For example, R1 and R2 might identify two component-bearing regions, while F1 identifies the connecting flex. These identifiers should appear in the stackup, mechanical drawing, assembly drawing and review notes. Do not use colour alone to convey the regions, because printed drawings and exported files may lose the colour distinction.
For each region, describe the task: component support, enclosure mounting, signal interconnection or motion. Distinguish a flex span that is formed once from one that moves during service. Show the boundaries using dimensions tied to stable datums. If the rigid outline and the end of the rigid material are different features, identify both. A viewer should not need to infer a material boundary from the component placement or an artist's impression of the finished product.
The region map also defines where a requirement applies. An overall thickness for R1 does not automatically apply to F1, and a keepout for a moving span may be different from a component clearance on a rigid island. Note which constraints are fixed by the enclosure and which may change during the stackup review. The rigid-flex manufacturing hub supports construction selection; the map carries the selected concept into a specific release. Before proceeding, ask a reviewer to identify each region and its function from the drawing alone. If they cannot, correct the map before adding more detail. This simple check prevents later discussions from using the same label for different physical areas.
Map global copper layers to each regional stack

A global layer number should retain one meaning across the design. A six-layer rigid region can contain only a subset of those conductive layers through the flexible span. If global layers L3 and L4 continue through F1, do not relabel them locally as L1 and L2 without an explicit mapping. Otherwise a drill table or impedance note can refer to the wrong physical layer even though each individual drawing appears plausible.
Create a table with global layer ID, electrical function, presence in each region, material interfaces and relevant thickness. Separate conductive layers from coverlay, bonding films and mechanical reinforcement. Include the copper construction and finished thickness interpretation where needed. Material names should identify a proposed product or an agreed specification, not a collection of vague categories such as “standard PI.” Alternatives should be visible and require review against the electrical and mechanical constraints.
For an illustrative map, R1 and R2 contain L1 through L6, while F1 contains only L3 and L4 with its local protective structure. This is a conceptual example, not a qualified stackup. It creates immediate questions about the transition, bonding sequence and hole spans. A via connecting L1 to L3 belongs to a region where both layers exist; placing the same via definition in F1 is inconsistent. Use the flex regional stackup method to calculate the flexible portion rather than using the rigid total. This mapping should be reconciled with the CAD layer manager and exported files. A drawing cannot compensate for a mismatched database definition that generates incorrect manufacturing outputs.
Specify holes, openings and transitions by region

The hole table needs more than diameter and quantity. Identify plated or nonplated function, start and end layers, region applicability, finished or tool-size meaning and any fill or cap requirement. A hole that is straightforward in a rigid island can be inappropriate in the intended moving span. Check the full motion envelope and the transition details before placing interconnects close to a material boundary.
Coverlay and reinforcement drawings should use the same datums as the region map. State the required exposed contact areas and mark critical openings. If a local stiffener is present, identify its side, material and bonding method. A rigid-flex board can still contain local mechanical reinforcement, but it should not be confused with the electrically connected rigid construction. The coverlay opening guide provides the exposure and allowance questions; the fabrication package needs the actual agreed values or clearly marked unresolved items.
At a transition, show where the different materials end and where bending is intended to begin. Do not prescribe a generic transition clearance without checking the construction and assembly process. Also review copper and component placement on both sides of the boundary. A keepout that appears adequate in the flat view may be violated by the installed bend or by a fixture during reflow. If the supplier proposes an adjustment, update the controlled region drawing and affected output files together. Retaining an email exception while issuing an unchanged drawing creates ambiguity for repeat orders. A useful release includes a short change table identifying the modified region, reason, affected files and approval, so future reviewers can trace the construction without searching a long correspondence thread.
Show both the flat build and the installed shape

The flat drawing defines the manufactured outline and material regions. The installed drawing defines how the assembly fits the product. Both are necessary when a flex span changes shape, and neither should be assumed to replace the other. Identify the view direction, datum, bend axis and the face that lies inside the bend. A fold arrow without orientation can be interpreted differently when the drawing is viewed from the opposite side.
State whether a radius is an inside surface radius, a centreline radius or another defined reference. Include the required free length and the positions of restraints. If the bend moves, show the limiting positions and travel instead of only one attractive three-dimensional pose. If the board is formed once, document the intended forming and installation sequence so handling does not create a tighter temporary bend than the final geometry.
Use an illustrative two-island model to check consistency. In the flat state, the islands are connected by F1 and the components face the specified side. After folding, verify that connector access, mounting holes and component envelopes match the enclosure. A mirrored component-side error can survive a simple outline check but become obvious when the assembly sequence is shown. Include service access and any need to reopen the product. The installed model should not imply that the bare board arrives preformed unless that operation is explicitly ordered. Finally, label explanatory views as schematic when they are not dimensionally controlling. The reader should know which drawing establishes the manufactured geometry and which explains the intended use, especially when screenshots from several design tools are combined in one package.
Define verification and assembly responsibilities

A complete package identifies which checks belong to bare-board fabrication, which belong to assembly and which belong to the finished product. Electrical continuity of the bare board does not establish solder-joint integrity or bend life. A successful fit check does not establish controlled impedance. List the required evidence and its scope so a quotation does not silently omit a test that the customer expects.
For assembly, include component data, placement information, side sequence and any carrier requirements. The rigid-flex assembly guide explains why support and thermal profiling need the actual construction. If a fixture contacts a flexible region, identify the contact and review it rather than assuming all support occurs on the rigid islands. Keep temporary tooling separate from permanent product material in the drawings.
For qualification, define the construction and process revision represented by the samples. Record the relevant motion, environment and thermal exposure. If testing uses a coupon, explain what critical features it represents and what it does not. Do not present a generic material certificate as product qualification. A practical evidence matrix has columns for requirement, specimen or document, method, acceptance basis and responsible party. Unknowns should remain visible until resolved. This makes an early enquiry useful even before the entire test plan is complete. It also gives purchasing a way to compare equal scopes. When a supplier offers a different material or process sequence, the matrix shows which evidence needs reconsideration instead of leaving the team to assume that the alternative is covered by earlier results.
Perform a release cross-check before requesting the build

Export the manufacturing data, then review those outputs independently of the editable CAD project. Confirm that the outline, copper, drill groups, coverlay and region map share the same origin and revision. Compare the global layer names in the file set with the stackup table. Open the outputs in a viewer and inspect a representative feature in every region; a successful export message is not evidence that the intended structure was exported.
Include a manifest listing file names, roles, revision and the precedence for resolving conflicts. Avoid relying on file timestamps as the sole version control. If a material or stackup is still provisional, mark the package as a review release and list the decisions that remain open. Do not mix production artwork with a preliminary drawing without explaining the status. The downloadable region worksheet is intended to expose those gaps before an order is placed.
Submit the package for manufacturing review with prototype and production quantities, required delivery, assembly scope and evidence needs. Ask for a response against the region and layer identifiers so proposed changes can be applied precisely. Before authorizing the build, reconcile every accepted change into the controlled files. Retain both the approved package and the review record; do not overwrite the earlier release without a trace. A strong rigid-flex package is not necessarily large. It is internally consistent, makes the intended construction reproducible and distinguishes required performance from unverified assumptions. That is what allows manufacturing, assembly and the customer to work from the same definition rather than solving different versions of the product.
Use the IPC document-status index to check the standards named in the project specification; the index itself does not define the acceptance criteria.
Region and bend workbench
Use consistent layer numbering and actual finished thicknesses. The calculator checks one contiguous flex span; it does not infer bonding materials or approve a manufacturing process.
Rigid-Flex Region & Bend Workbench
Optional transmission-line estimate
For an initial homogeneous-line comparison, use this shared engineering model. Covered flex and transitions need a more complete electrical model.
Open the preliminary line calculator
Rigid-Flex Preliminary Transmission-Line Planner
Continue with the next engineering decision
Preparing the CAD handoff? Compare KiCad and Altium rigid-flex release requirements for region definitions, bend drawings and manufacturing outputs. The released files must describe the intended construction regardless of the CAD editor.
Once the rigid-flex construction is defined, review the broader PCB manufacturing and production-release scope to align fabrication data, inspection and the supply request.
Reference documentation
Use the documentation for your installed software version and the selected material grades. Altium rigid-flex design documentation describes its region and bending workflow. These references support design communication; they are not manufacturing approval for a particular board.
Send a complete project brief
Include the flat outline and installed view, layer/region mapping, material grades, finished thicknesses, bend duty, copper artwork, drill information and quantities. Add the BOM, placement file and acceptance requirements when assembly is included.
Mark unresolved choices rather than guessing. Download tool results if they help describe your request. Contact does not automatically receive calculator inputs.