RAYPCB · ENGINEERING GUIDE
ITEQ IF-FC Coverlay: Openings, Flow and Copper Coverage
ITEQ IF-FC is a coverlay series, used to protect circuit features rather than supply a copper-clad base. ITEQ also lists qualified suffix variants and separate low-loss coverlay families. This guide focuses on pad openings, registration and adhesive occupancy so that the selected coverlay is specified as part of a finished flex construction.

Separate the film from the opening
The design must identify the coverlay product, film and adhesive dimensions, aperture artwork and placement datum. A nominal hole in the artwork does not guarantee the same clear opening after lamination. Resin movement and registration can change the exposed contact area. Define the finished feature that the assembler or connector actually needs.
Construction and decision boundaries
| Review item | What this page establishes | What remains project-specific |
|---|---|---|
| Material role | Coverlay protects patterned circuitry | Not copper-clad base material. |
| Aperture | Usable pad area after registration and flow | Artwork alone is not the finished opening. |
| Suffix | Normal and qualified variants separate | Do not transfer neighboring-grade data. |
Review one pad boundary carefully
Show the land, intended exposed area and permitted encroachment. Include the relative position of a nearby stiffener or component support. If the allowed window is small, ask for a fabrication review before releasing the footprint. Do not apply a universal oversize allowance without the product, process and registration capability that justify it.
| Review item | What to establish |
|---|---|
| Opening | Minimum usable pad exposure after pressing |
| Registration | Aperture, pad and stiffener datums |
| Grade | Exact IF-FC suffix and controlled sheet |
| Limit | Fill volume does not predict aperture encroachment |
Use copper occupancy to frame the process question
The fill worksheet estimates ideal space around a patterned conductor plus a continuous separation above it. It does not calculate adhesive flow into an aperture or the actual required film gauge. Local pattern density, the opposing surface and process conditions matter. Send the copper map with the coverlay data rather than choosing adhesive only from average copper weight.

Copper-clearance volume illustration
Copper-clearance volume illustration
Use the current inputs and keep the assumptions
Start with the example only to inspect the units and the calculation boundary. Replace every assumption with a value tied to your own document or measurement. An empty numeric field is not zero. The review-reference field is a local label; avoid entering customer names, confidential part numbers or other private information into a public worksheet.
After calculating, read the notes alongside the numerical result. Changing any input invalidates the displayed result and disables its download until you calculate again. For a comparison, keep the units, geometry, material condition and measurement boundary consistent. A long decimal result does not imply equally precise input data. The downloadable record stays on your device and can be attached manually to an inquiry. It is not automatically transferred into the Contact form.
If an input is unknown, identify the person or document needed to resolve it. Do not fill a gap with a favorable generic value simply to obtain a result. You can request a material or fabrication review without using the tool. The arithmetic illustrates a relationship; it does not accept a construction, certify a material, establish current pricing or replace a supplier process specification.
| Input | What to establish before using it |
|---|---|
| Review reference | Nonconfidential revision label. |
| Evaluated bond area · mm² | Panel or coupon area with consistent pattern coverage. |
| Copper feature height · µm | Height of the one patterned surface being evaluated. |
| Retained copper coverage · % | Area fraction occupied by copper on that surface. |
| Final separation above copper · µm | Ideal continuous bondline above the highest copper; excludes roughness and glass. |
Optional cost comparison from your own allowances
Use a quotation or a clearly labeled internal assumption for each input. Keep the quantity, construction and inspection scope the same when comparing alternatives. This uncalibrated planning model adds entered values; it contains no current market rates and does not issue a RAYPCB quotation. You can contact the team without completing it.
Optional project allowance comparison
Preserve the exact grade variant
The current official page separates normal IF-FC from anti-CAF variants and other coverlay families. Those labels do not permit transferring every electrical or humidity result into the base IF-FC specification. Use the exact suffix and controlled sheet required by the project. Chemical declarations and finished-circuit bias testing also answer different questions.
Keep neighboring material roles distinct
IF-BC bondply addresses bonding between surfaces, while IF-E requires recovery of the base-laminate identity. Kapton FN is an FEP-coated film task, not a default replacement for a flex coverlay. Review the material set as a construction while preserving the specification of each component.
Request a finished-opening review
Provide aperture data, land geometry, copper thickness, registration datums and the minimum acceptable exposed area. State which contacts are inspected before and after assembly. Ask the supplier to return a proposed product and process allowance, with unresolved details flagged. Compare quotations with the same opening and inspection requirements, not merely the same coverlay family name.
Release the material with its finished flex construction
Coverlay openings are a mechanical registration problem as well as an insulation problem. Establish the minimum usable pad area after placement and adhesive movement. Describe allowed encroachment and the inspection point. Avoid assuming that artwork opening size equals the clear opening after pressing. A protective film system and a liquid solder-mask system need their own design and process review.
Start the release drawing with the shape the circuit will occupy in the product. Show the flat outline, assembled position, motion envelope and regions that must remain flat. Identify installation folds separately from movement during service. A flex that is bent once to clear an enclosure has a different verification problem from a cable that moves on every operating cycle. State the mechanism, travel, speed, temperature and expected duty rather than writing only flexible PCB.
Then define each cross-section that actually exists. The bend span, connector tail, component island and rigid transition may have different copper, coverlay, adhesive and stiffener layers. A single finished-thickness number cannot describe all of them. Indicate the measurement locations and include tolerances where fit or electrical behavior depends on them. Ask the fabrication team to return the proposed construction for approval before it becomes a purchasing assumption.
Copper deserves its own record. Distinguish supplied foil from copper remaining after imaging, etching and plating. Identify which surfaces receive additional metal and whether the bending region is plated. The foil process label alone does not establish fatigue life: thickness, grain direction, surface treatment, pattern shape and mechanical restraint also affect the construction. Do not select a copper variant solely because a comparison table calls it the premium option.
Choose verification coupons to reproduce the critical feature. A flat electrical coupon can check continuity or a specified transmission geometry; it does not reproduce repeated motion around a hinge. A bend specimen needs the relevant stack, trace layout, radius definition, temperature, cycling method and failure criterion. Monitor the failure mechanism of interest and keep the sample count with the result. A successful demonstration is useful evidence, but its scope must remain attached to it.
Review assembly as part of the material decision. Components and connectors impose local mass and force, and the support tooling changes how a flexible panel moves during printing, placement and heating. State component keep-out regions, supported areas and the sequence in which temporary supports are removed. A material thermal test is not the oven profile for the populated assembly. Moisture conditioning and permitted thermal exposure need a product-specific instruction.
For purchasing, separate the recurring board cost from tooling, fixtures and qualification. Compare the same quantity, panel assumptions, copper, surface finish, inspection and delivery format. An inexpensive laminate can become an expensive assembly if it requires extra handling or poor nesting. Conversely, a more elaborate stack should solve a stated need; adding layers or thicker copper without an electrical or mechanical reason can create unnecessary work.
Prepare a concise inquiry package even when some inputs are unknown. Include the schematic or connection requirement where relevant, fabrication data, stack sections, mechanical drawing, quantity and a short list of open decisions. Mark exact-material requirements separately from permitted alternatives. Keep the previous approved revision available for repeat builds. The engineering conversation can start with an incomplete stack, provided the missing items are explicit and no unapproved substitution is presented as settled.
Standards, source context and limits
Use the edition, amendment and material-document revision named in the purchase agreement. A standards title, marketing label or supplier product family does not establish that a particular lot meets a requirement. Public summaries are useful for scope; the controlled specification and applicable test method govern acceptance.
The examples on this page are illustrative engineering scenarios. They are not RAYPCB production records or guaranteed material values. Source links identify the organizations responsible for the referenced information. Confirm applicability to the exact grade, construction and test condition before carrying a number into a drawing or qualification report. For a flex board, distinguish the design requirements in IPC-2223, finished-board qualification and performance in IPC-6013, and the material scopes of IPC-4202, IPC-4203 and IPC-4204. These cover different deliverables; naming them does not certify the material or factory. State the contracted revision and applicable material sheet. Source review date: 3 October 2026. Legacy designation, present availability and an approved replacement are separate questions.
For fabrication scope and the agreed construction requirements, see PCB manufacturing.