RAYPCB / Manufacturing specifications

Rigid-Flex PCB Manufacturing Capabilities

Review the complete rigid-flex construction, then check the rigid and flexible regions against their own geometry and process limits.

Rigid-flex panel with separate rigid islands and flexible interconnect regions.
Rigid-flex panel with separate rigid islands and flexible interconnect regions.
Total rigid-flex layers
2–32
Flex layers within the stack
1–12
Flex geometry at 0.5 oz
4 / 4 mil
Impedance review windows
±10% / ±7%

Full process capability tables

Use the matching construction and production window. Dimensions, copper and via limits must be reviewed together; an extended capability is confirmed against the released drawing.

Capability tables (CSV)

Region construction & materials

Region construction & materials
ParameterSpecificationApplication notes
Rigid-flex total layers2–32 layers
Flexible layers (within)1–12 layers
Rigid base materialFR-4 (High-Tg 150 / 170 available)
Flex base materialPolyimide (PI / Kapton), PET, PEN
CoverlayPolyimide coverlay on flex areas
StiffenersFR4, aluminum, polyimide, stainless steel
Finished thickness (rigid-flex)0.06–4.0 mm; define rigid and free-flex regions separately
Copper weightFlex 1/3 oz – 2 oz · rigid heavy copper to 12 oz
Flex-section min trace / space0.5 oz: 4/4 mil · 1 oz: 5/5 mil · 2 oz: 5/7 mil
Through-hole aspect ratioUp to 10:1 referenceApply to the through-hole depth/diameter definition, not a laser microvia.
Blind-via aspect ratioUp to 0.75:1 referenceConfirm dielectric depth, opening definition and the selected manufacturing process.

Flexible copper is part of the total layer count, not an addition to it. Flex copper limits apply only to the flexible region; high copper weights belong to rigid-region review.

Rigid-region conductors & holes

Rigid-region conductors & holes
ParameterMass productionPrototype / extended reviewApplication notes
Min. inner-layer clearance3 mil3 mil
Min. line width3 mil (0.0762 mm)3 mil (0.0762 mm)
Min. line space3 mil (0.0762 mm)3 mil (0.0762 mm)
Min. hole size0.1 mm0.1 mm0.1 mm drill/process entry; earlier finished-hole reference is 0.152 mm. They are not equivalent dimensions.
Min. plated hole copper25 µm25 µmPlated-through-hole reference; specify average/local minimum and acceptance class.
Min. blind / buried via0.1 mm0.1 mm (1–18 layers)Define layer span, depth and opening diameter; confirm the complete via map.
PTH dia. tolerance±0.076 mm (≈±3 mil)±0.076 mm (≈±3 mil)
NPTH dia. tolerance±0.05 mm (≈±2 mil)±0.05 mm (≈±2 mil)
Hole position deviation±0.05 mm (≈±2 mil)±0.05 mm (≈±2 mil)

The 3 mil conductor values below refer to rigid regions. Use the copper-dependent flex values in the construction table for flexible tails. Confirm finished-hole diameter separately from drilling.

Rigid-region copper, mask & marking

Rigid-region copper, mask & marking
ParameterMass productionPrototype / extended reviewApplication notes
Heavy copper (rigid)4 oz (nominal ≈140 µm)up to 12 ozReview copper with line/space and construction; do not combine independent minima.
Min. solder-mask bridge0.1 mm (≈4 mil)0.1 mm (≈4 mil)
Solder-mask colourGreen, Black, Blue, White, Yellow, RedGreen, Black, Blue, White, Yellow, Red
Silkscreen colourWhite, Yellow, Red, BlackWhite, Yellow, Red, Black
Peelable maskTop, bottom, double-sidedTop, bottom, double-sided

A 12 oz rigid-region option does not qualify a 12 oz flexible tail. Review copper balance, transition geometry and lamination for the complete board.

Profile & mechanical processing

Profile & mechanical processing
ParameterMass productionPrototype / extended review
Outline methodRouting, V-groove, beveling, punchRouting, V-groove, beveling, punch
Outline tolerance±0.15 mm (≈±6 mil)±0.15 mm (≈±6 mil)

Specify each rigid outline, flex outline and transition boundary. V-scoring is a rigid-area option and must not cut a flexible interconnect.

Electrical & reliability requirements

Electrical & reliability requirements
ParameterMass productionPrototype / extended reviewApplication notes
Controlled impedance±10%±7%Agree signal/reference layers, geometry, coupon and test method.
Insulation resistance1 × 10¹² Ω (normal)1 × 10¹² Ω (normal)Confirm temperature, humidity, conditioning and test voltage.
Through-hole resistancePer approved continuity test planPer approved continuity test planContinuity threshold and unit must be specified in the electrical-test plan.
Thermal shock3 × 10 sec @ 288 ℃3 × 10 sec @ 288 ℃Confirm specimen, conditioning, cycles and acceptance method; not an operating-temperature rating.
Warp & twist≤ 0.7%≤ 0.7%Define the panel/board condition and measurement method.
Electric strength> 1.3 kV/mm> 1.4 kV/mmMaterial test reference; confirm test method and dielectric construction.
Peel strength1.4 N/mm1.4 N/mmConfirm laminate, copper, conditioning and test method.
Solder-mask hardness reference> 6H> 6HReference >6H; specify the hardness test method. Do not interpret this as an abrasion-life rating.
Flammability94V-0 material / construction option94V-0 material / construction optionFor the selected recognized material/construction; request the applicable UL file and thickness range.
Test voltage50–330 V50–330 VElectrical-test setting; not rated operating voltage.

Impedance must be reviewed across transitions. Flatness, thermal stress and peel criteria require defined specimens and conditions; they do not replace bend-life qualification.

Materials & surface finishes

Select the rigid laminate, flexible film, adhesive, coverlay and no-flow prepreg as one compatible system. Finish options include ENIG, ENEPIG, OSP, immersion silver / tin, and electrolytic hard gold / gold fingers.

State the finish and required thickness or specification on the drawing. Material ratings and finish acceptance apply to the selected construction.

Engineering decisions before release

Layer mapping & region boundaries

Identify exactly which layers continue between rigid islands. Draw no-flow prepreg, coverlay, adhesive and local reinforcement extents.

Rigid-flex stackup and layer mapping

Air gaps & bookbinding

Unbonded flex layers can change bending behaviour. Define lengths, edge treatment and mechanical duty rather than assuming a universal bend improvement.

Air-gap construction guidance

HDI in rigid areas

Show stacked or staggered via spans and the lamination order. Keep microvia depth ratios separate from through-hole aspect ratio.

Rigid-flex manufacturing sequence

Check the rigid and flexible layer map

Open the rigid-flex region workbench

Prepare the region stackup and export the result if useful. The workbench is a planning aid; the capability tables remain the reference for your drawing review.

RAYPCB ENGINEERING

Rigid-Flex Region & Bend Workbench

Project Preparation
Loading Rigid-Flex Region & Bend Workbench…
Using this tool & sharing results

Use the stated units, input limits and model assumptions. Results support an engineering discussion; they do not approve a design, process or production order.

After changing inputs, update the result before using it. Where a download or copy action is available, review that brief and attach or paste it into your enquiry. Opening Contact does not transfer these inputs or send a request.

How to use and share tool results

Inspection evidence for your supplier review

Agree IPC-6013 for flexible / rigid-flexible board performance and IPC-A-600 for board acceptability, including revision, class and customer requirements. Request the relevant evidence against the part number and drawing revision.

IPC standards and their scope help separate manufacturing requirements from acceptance criteria.

  • Current ISO 9001 documentation and applicable UL file / construction scope for supplier qualification.
  • Approved drawing, material identification, lot traceability and agreed inspection records.
  • Dimensional, electrical-test and any specified coupon / microsection results.

Quality system and supplier documents · Inspection workflow · Equipment and process evidence

Multilayer pressing equipment — the process sequence follows the approved region stackup.
Multilayer pressing equipment — the process sequence follows the approved region stackup.

Rigid-Flex capability questions

Is a six-layer rigid-flex with two flex layers an eight-layer board?

No. If the two flexible copper layers continue within the six-layer rigid stack, the total is six. The region map must show which two layers continue.

Can I apply the rigid-region minimum line width to the flex?

Use the flex line/space entry for its copper weight. The rigid-region table is not an interchangeable flex design rule.

What does the 0.06–4.0 mm thickness range describe?

It is the construction range requiring region-specific definition. State the thickness of every rigid region and free-flex region separately; it is not a universal bending thickness.

Send the drawing. Define the build.

Send what you have. Mark any requirement where you need an engineering recommendation, and identify the current revision.

  • Gerber / drill files and a drawing identifying rigid islands and flexible zones.
  • Total layers, continuous flex layers and finished thickness for each region.
  • Via map, stackup, coverlay, stiffeners and any unbonded flex areas.
  • Installed shape, bend duty, assembly needs, test requirements and quantity.

Ready for a manufacturability review?

Upload the files through Contact. The reply can define pricing, delivery, process exceptions and the agreed test scope.

Send files for an exact quote

sales@raypcb.com