RAYPCB · ENGINEERING GUIDE
MEGTRON 7 R-5785: N, GE and GN Construction Data
MEGTRON 7 R-5785 is a family of laminate constructions whose suffix matters. N, GE and GN entries cannot be reduced to one universally applicable dielectric constant. This guide helps read the material data and identify the construction that belongs in a PCB stackup.
For channel allocation and generation selection, use the separate MEGTRON 7 PCB guide. This page owns the exact material callout, characterization context and the limited dielectric-loss calculation.

Preserve N, GE and GN in the request
Panasonic's R-5785 documentation distinguishes low-Dk-glass and E-glass variants and their associated R-5680 prepregs. Copper variants also matter. Ask for the exact laminate, bonding material and foil combination rather than requesting an unspecified MEGTRON 7 board.
The current global sheet and regional tables may use different frequencies and rounded values. Keep one controlled source with the construction proposal. Do not choose the smallest Dk from one table and the smallest Df from another without establishing that they describe the same specimen.
Construction decisions at a glance
| Review focus | Established context | Design boundary |
|---|---|---|
| N / GE / GN | Different reinforcement and foil context | Keep exact suffix. |
| Data revision | Frequency and method retained | Do not average tables. |
| Tool | Dielectric-only attenuation | No conductor or transition contribution. |
Separate characterization from the design input
A material's published permittivity is measured using a defined method. A design input may additionally depend on glass style, resin content, dielectric thickness and the intended field distribution. Preserve the reason a number was chosen for the simulation.
For a microstrip, air and coating can change the effective propagation environment. The bulk value in a laminate table is not automatically the effective Dk of that route. A stripline approximation also needs the actual surrounding dielectric construction.
| Review item | What to establish |
|---|---|
| Identity | N, GE or GN plus associated bonding and copper |
| Data | One controlled method, frequency and construction |
| Model | Dielectric component only, homogeneous TEM |
| Boundary | No complete channel or supply approval |
Use dielectric attenuation as one component
The tool illustrates the low-loss homogeneous TEM dielectric term using frequency, Dk, Df and length. Its purpose is to expose the sensitivity of that one term. It excludes conductor roughness, copper loss, connectors, vias and field inhomogeneity.
Do not compare its result directly with a measured end-to-end channel and call the difference a material defect. Align the reference planes and model boundary first. Any decimal precision shown is arithmetic precision, not evidence that the material input is equally certain.

Homogeneous TEM dielectric loss illustration
Homogeneous TEM dielectric loss illustration
Use the current inputs and keep the assumptions
Start with the example only to inspect the units and the calculation boundary. Replace every assumption with a value tied to your own document or measurement. An empty numeric field is not zero. The review-reference field is a local label; avoid entering customer names, confidential part numbers or other private information into a public worksheet.
After calculating, read the notes alongside the numerical result. Changing any input invalidates the displayed result and disables its download until you calculate again. For a comparison, keep the units, geometry, material condition and measurement boundary consistent. A long decimal result does not imply equally precise input data. The downloadable record stays on your device and can be attached manually to an inquiry. It is not automatically transferred into the Contact form.
If an input is unknown, identify the person or document needed to resolve it. Do not fill a gap with a favorable generic value simply to obtain a result. You can request a material or fabrication review without using the tool. The arithmetic illustrates a relationship; it does not accept a construction, certify a material, establish current pricing or replace a supplier process specification.
| Input | What to establish before using it |
|---|---|
| Review reference | Nonconfidential revision label. |
| Frequency · GHz | Single frequency; use Df/Dk for this frequency and method. |
| Relative permittivity | Homogeneous bulk permittivity, not an inferred microstrip effective value. |
| Loss tangent Df | Small-loss approximation; the model accepts less than 0.1. |
| Uniform path length · mm | No connector, via or conductor-loss contribution. |
Optional cost comparison from your own allowances
Use a quotation or a clearly labeled internal assumption for each input. Keep the quantity, construction and inspection scope the same when comparing alternatives. This uncalibrated planning model adds entered values; it contains no current market rates and does not issue a RAYPCB quotation. You can contact the team without completing it.
Optional project allowance comparison
Treat specialty foil as a distinct construction
A buried-resistor version requires a different artwork and verification discussion. The R-5775(S) guide explains why resistive foil cannot be handled as ordinary signal copper. Panasonic also documents a separate MEGTRON 7 buried-resistor construction.
Preserve sheet resistance, foil combination and the circuit's tolerance and power requirements when that option is relevant. Do not assume a standard R-5785 suffix carries a buried-resistor layer unless the exact product documentation and quotation state it.
Compare a later family without changing the boundary
The R-5795(N) guide addresses a MEGTRON 8 low-Dk construction. Compare it against the same line geometry assumptions, frequency and copper basis when studying a migration. Recalculate impedance geometry if the dielectric properties or available thickness change.
Material selection and sourcing should proceed together. Ask which core and prepreg combinations can actually support the proposed stackup and what qualification evidence is required before the change can be released.
Issue a construction-specific inquiry
Include the full R-5785 suffix, R-5680 bonding selection, glass, copper, dielectric targets, board dimensions and quantity. Attach the relevant source revision and state whether the drawing permits alternatives. Identify the electrical evidence needed for acceptance.
The Panasonic portfolio remains available for broader material questions. A focused review can proceed without completing the calculator; a downloaded result is simply an optional explanation of the assumptions you want checked.
Tie the exact grade to an electrical construction
State the channel reference planes, frequency range, routing length, copper construction, transitions and interface assumptions together. A laminate loss-tangent value is one input to that system. It is not a complete insertion-loss measurement or a guarantee that a data rate will work.
Use comparable measurement or modeling conditions when screening alternatives. Material changes can require geometry changes to preserve impedance, and copper roughness can alter the result independently of the resin system. Keep the proposed stackup and the channel analysis synchronized through fabrication review.
For procurement, identify the properties that are fixed and the alternatives that can be evaluated. Request evidence at the relevant construction and frequency rather than a broad low-loss label. Compare total delivered scope and validation effort alongside material price. A shorter or better-routed channel may change the tradeoff more than replacing a material name alone.
A useful design-data record retains both the material value and the reason it was selected. State whether the value is supplier characterization, a construction-specific design input, a measured coupon extraction or an early assumption. These sources are not interchangeable. Keep frequency, method and specimen information visible when a comparison uses more than one document.
The tool on this page starts empty because a plausible default can otherwise be mistaken for a verified grade profile. Use the example to understand the units, then replace it with project inputs. A result with many decimal places does not imply that the material or routing-loss input is known to that precision.
For a high-speed design, plan how the model will be checked. Reference planes, coupon geometry, fixtures and the acceptance boundary determine what a measurement means. A coupon that characterizes one line construction does not automatically qualify every route or transition on the board.
Keep the commercial comparison aligned with the engineering one. Quantity, copper, layer structure, test deliverables and qualification effort should be comparable. A lower material allowance can be irrelevant if the proposed construction cannot meet the channel requirement, while a premium grade may be unnecessary if the actual route already has sufficient validated margin.
Standards, source context and limits
Use the edition, amendment and material-document revision named in the purchase agreement. A standards title, marketing label or supplier product family does not establish that a particular lot meets a requirement. Public summaries are useful for scope; the controlled specification and applicable test method govern acceptance.
The examples on this page are illustrative engineering scenarios. They are not RAYPCB production records or guaranteed material values. Source links identify the organizations responsible for the referenced information. Confirm applicability to the exact grade, construction and test condition before carrying a number into a drawing or qualification report. Sources were reviewed on 3 October 2026. A public catalog search is not proof that an unlisted product never existed. Where the exact designation or current technical sheet could not be verified, this page provides a clarification workflow rather than an invented material specification. Current supply, construction availability and qualification remain separate questions.
For fabrication scope and the agreed construction requirements, see PCB manufacturing.